Factory Monitoring - Details

The details of Factory Monitoring show information by Machine, with fields considered in a given indicator, for both analysis and confirmation of the indicator. It also proposes a comparison of Projected X Performed values precalculated during the Target Calculation, making it easier to identify divergences for immediate/future action.

Indicators

This routine provides the following indicators:

NEE (Net Equipment Effectiveness) – the chart displays Actual Quality % and Effectiveness %; the composition table of the Item displays Projected Time, Projected Amount, Actual Reported Amount, Actual Scrapped Amount, and Actual Reworked Amount.
OEE (Overall Equipment Effectiveness) – the chart displays Actual Availability % and NEE %; the composition table of the Indicator displays, by Machine, Projected Capacity, Actual Capacity, Effectiveness % and Actual Stop.
TEEP (Total Effective Equipment Performance) – the chart displays Use % and OEE; the composition table of the Indicator displays, by Item, Projected Time, Actual Capacity and Actual Amount.
Tk (Takt Time) – the chart displays Projected Tk and Actual Tk; the composition table displays Projected Capacity, Projected Amount, Performed Capacity and Performed Amount.

 

Procedures

 

Important:

The BTS indicator is only displayed when the Target x Machine has a target component to indicate the sequence of operations.